Fan / Separator H2SO4 (Sulfuric Acid)
is Designed to Remove Fume and Other
Contaminants from the Air Stream. FAN / SEPARATOR SPECIFICATIONS Various materials of construction may be used to resist corrosive contaminants and scrubbing liquor
that come into contact with the unit. Tri-Mer Corporation holds the U.S. Patent #3,616,604 for and
has been manufacturing Fan/ Separator Units since 1966. Our Fan/Separator Units can be fabricated from PVC, Polypropylene, Fiberglass Overlayed PVC,
316 Stainless Steel, 304 Stainless Steel and Mild Steel. All units are Factory Tested. Units are
available from 50 to 100,000 cfm. Every Fan / Separator unit is constructed of the most state of the art fabrication techniques using
fusion, extrusion welding, and seamless corners wherever possible. Bolted access doors are
provided for inspection of the interior and removal of the filter elements. Gasket made from closed
cell PVC foam is provided. Hardware is 316 S.S. maximum bolt torque 10#. OPERATING CONFIGURATION The scrubbing liquor wets the contaminant as it enters the fan and allows it to be centrifugally spun
out on the fan scroll through a process on dynamic mixing. The centrifugal action, using the fan
wheel as part of the scrubbing process, will eliminate approximately 55 percent of all contaminants
in the air stream. Scrubber to be of two-stage design with dynamic scrubbing as the first stage and
the second stage to be an impingement process. The impingement process causes the air to change direction as it passes across the rigid packing
media. The packing media also acts as a mist eliminator section. The packing media is supplied in
framed packs and is suitable for 99 percent removal efficiency of 20 micron and larger water droplets
under continuous a duty load. The scrubber contains a Venturi evacuation drain for continuous
removal of scrubbing liquor. The Fan / Separator is a dry sump system and will contain only
residual liquid passing through the scrubber during any phase of operation. 1) INTENT This Specification defines the design requirements, the quality and types of workmanship and
materials, and the performance standards and guarantees for equipment, materials and services
supplied by Tri-Mer Corporation. 2) SCOPE The vendor (Tri-Mer Corporation) shall furnish Fan / Separator Units complete with auxiliaries and options described herein. Each system shall include but is not limited to the following:
- The Fan Separator and internals necessary to provide adequate liquid-process stream
contact in order to achieve performance.
- Mist eliminator to achieve entrained liquid separation.
- Flanged connections for all external water fill, water makeup and drain piping as
required and optioned.
- Controls if optioned, to automatically feed water, and monitor pressure.
- Complete shop coating of required areas with Epoxy or other resistant paint for
external surfaces.
3) SEPARATOR DESIGN REQUIREMENTS
- Fan / Separator Units shall be of low energy type. Internals shall be designed to
prevent the buildup of solids.
- Fan / Separator Units shall be manufactured of PVC, Polypropylene, Stainless steel or Mild steel. Vendor shall evaluate materials and select the most appropriate material for this service.
- Scrubber to be complete with Fan and Separator section designed and manufactured together
as an integral-operating machine.
- Separator Section shall be provided with clear view-ports designed for accessibility and
inspection of equipment during operational phase.
- Inspection ports shall be placed in proper positions to facilitate the ease of operation
and inspection.
- Flanged pipe connections shall be provided for the introduction of water as well as drainage.
- Contaminants shall enter the eye of the fan where they are treated with a fog mist
of scrubbing liquor.
- The fan and motor shall be designed for a static pressure capability of the specified pressure
drop through the Fan / Separator plus external pressures for the customers ductwork losses.
- The sound levels generated by the Vendor furnished equipment during normal operation
shall not exceed 85 dBA-weighted, slow response, under free field condition, at a horizontal
distance of 10 feet from the surface of sound generation.
- Vendor shall provide electric motor and drives for each unit. Vendor shall be responsible
for the selection of the motor characteristics and the motor mounting.
- All electrical equipment provided by the vendor shall be supplied in NEMA rated enclosures.
- All equipment manufactured by Tri-Mer Corporation is warranted under the standard
Tri-Mer Corporation one-year warranty. All purchased components are warranted
under the respective manufacturer warranty.
4) STANDARD SUPPLIED COMPONENTS Standard Purchased components furnished on the Tri-Mer Corporation
Whirl/Wet Dust Collectors are as follows:
- Dwyer Magnehelic differential pressure gage for monitoring pressure across filter pack.
- ASCO or equal electrically actuated solenoid valve for inlet spray.
- Schedule 80 PVC plumbing.
- Hayward or equal valves.
- Vinyl tubing with traps for differential pressure connections.
- Fan section with standard EPACT 460/3/60 TEFC Motor.
5) COMPONENTS SUPPLIED BY END USER
- Tie downs, guy wires, anchor bolts and foundations.
- Field assembly.
- Field wiring.
- Fresh water and drain piping to supplied 150# flanges.
- Mating flanges to customer connections, hardware and gaskets.
- Connecting duct from process. (See Options).
- Heat tracing and insulation.
6) OPTIONS
- Electrical Control Panel: An electrical control panel with NEMA rated enclosure and fused
main disconnect switch. Designed for 460 volt / 3-phase - 60 hertz electrical supply.
Internal components of the control panel are pre-wired and terminal blocks are provided
for connection of external control components to be done by contractor. A motor starter to
operate the exhaust fan with pushbutton controls mounted on the front of the enclosure.
Power lines to the motor must be furnished and installed by the installation contractor.
Electrical devices are designed and built in accordance with the National Electric Code
(NEC). No other codes, standards, or specifications are followed unless a specific
agreement has been obtained in writing.
- Duct: Tri-Mer Corporation offers design and manufacture of duct systems in PVC,
Polypropylene and FRP.
- Re-circulation Tank: A remote tank with level control and pump, provided for
circulation of scrubbing liquor.
- pH Control System: Control of re-circulation tank pH level. pH Control System consists
of pH probe, Controller, and electric or pneumatic metering pump.
- PLC Interface:
A programmable logic controller (PLC) shall mediate control of system functions.
The programmable controller shall be mounted within the control panel enclosure. The programmable Logic Controller (PLC) shall be Allen Bradley or equal. See our Fan / Separator Q&A Page for more information. FAN / SEPARATOR | CASE STUDY | DRAWING | CHART Have a potential application? Contact Tri-Mer HOME l BUY ON-LINE l INTERNET SPECIAL
SELECT BY TRADE NAME l SELECT BY NEED
LITERATURE l PRESS RELEASES l CONTACT US Tri-Mer Corporation
1400 Monroe Street
P.O. Box 730
Owosso, MI 48867; USA
Phone: (989) 723-7838
Fax: (989) 723-7844
salesdpt@tri-mer.com © Copyright 2007 Tri-Mer Corporation
Website designed by Marketing Services Inc. |